IMPORTANT:

  1. Cold installation initiated from Ignite-UX server side using Ignite-UX version C.7.22.175 or later may fail for clients which were previously added or registered to Ignite-UX database while using C.7.21.150 or earlier version.
    If the client is Intel Itanium 9500 Processor Series based platforms or later, for successful cold installation, the client information needs to be refreshed with Ignite-UX database prior to cold installation with Ignite-UX version C.7.22.175.
    To refresh a client, select “Actions- > Refresh Client” option from the itool window of Ignite-UX server before cold installation is triggered with Ignite-UX version C.7.22.175 or later.
  2. Ignite-UX version C.7.22.150 ensures that cold installation of Veritas 6.1 proceeds only on those clients having supported platforms. The supported platform is Intel Itanium 9500 Processor Series-based platforms or later. During cold installation initiated from server side, the client platform verification check is wrongly performed in a specific cold-installation scenario, wherein the platform check is performed on the Ignite-UX server platform itself and not on the client, leading to cold installation failure with the following error message:
    ERROR: Base-VxFS-61 must be installed on Intel Itanium 9500 series based platforms or later
    NOTE: The installation initiated from client side works fine.
    This issue is fixed in Ignite-UX version C.7.22.175. For more information, see Ignite-UX version C.7.22.175 Release Notes.
  3. Version C.7.21.250 (May 2017, this version is suspended and unsupported). The version C.7.21.250 release of Ignite-UX is suspended and is unsupported due to a silent data corruption issue observed in the Ignite-UX restore operation. For additional details, see Hewlett Packard Enterprise Customer Advisory a00042181en_us. Contact Hewlett Packard Enterprise Response Center if you face any issues with Ignite-UX version C.7.21.250.

  For information on the supported versions of the Ignite-UX software supported on your environment, see the Ignite-UX Supported Version document at https://www.hpe.com/info/ignite-ux-docs.

 

 
Additional product information
Product #: IGNITEUXB     
Additional info
Global Trade ID: -
Version: C.7.22.175
Software specification: All 3 bundles(Ignite-UX-11-ALL_C.7.22.175.depot)
HP-UX 11i v1 (Ignite-UX-11.11_C.7.22.175_HP-UX_B.11.00_32_64.depot)
HP-UX 11i v2 (Ignite-UX-11.23_C.7.22.175_HP-UX_B.11.00_32_64.depot)
HP-UX 11i v3 (Ignite-UX-11.31_C.7.22.175_HP-UX_B.11.00_32_64.depot)
All 3 bundles (Ignite-UX-11-ALL_C.7.21.275.depot)
HP-UX 11i v1 (Ignite-UX-11.11_C.7.21.275_HP-UX_B.11.00_32_64.depot)
HP-UX 11i v2 (Ignite-UX-11.23_C.7.21.275_HP-UX_B.11.00_32_64.depot)
HP-UX 11i v3 (Ignite-UX-11.31_C.7.21.275_HP-UX_B.11.00_32_64.depot)
Installation
Select